BAM High Voltage Power Capacitor
Ntchito ndi Miyezo:
High voltage capacitor imagwiritsidwa ntchito kwambiri mu AC Power system yokhala ndi 50Hz kukonza mphamvu zamagetsi. The performance sonforms to GB 3083.2-89 《High voltage shunt capacitor》ndi IEC60871-1987.
GB/T11024-2010 National muyezo 《Ovoteledwa voteji 1kV kapena pamwamba shunt capacitors kwa kachitidwe mphamvu AC
JB/7112-2000 Machinery Viwanda muyezo 《Anasonkhana HV Shunt Capacitor
DL/T628-1997 Electric Power Viwanda muyezo 《Kusonkhanitsa HV Shunt Capacitor Kuyitanitsa Zofunikira Zaukadaulo》
Kagwiritsidwe Ntchito:
1.Altitude: zosakwana 1000m; Kutentha kozungulira: -40 ℃ ~ +40 ℃.
2.Palibe kugwedezeka kwamphamvu kwamakina, palibe mpweya woyipa ndi nthunzi, palibe magetsi, komanso kuphulika, komanso fumbi lophulika pamalo.
3.Kugwiritsira ntchito kopitilira muyeso: 1.00 Un, nthawi yayitali kwambiri, Kupitirira mphamvu: zochepa.1 Un.
4.Stable over-curent (kuphatikizapo ma harmonics panopa) osachepera 1.3 In.
5.With stand voltage: pakati pa terminal 2.15, nthawi yovotera masekondi 10, pakati pa ma terminals ndi chidebe 42kV kwa masekondi 10.
Makhalidwe apamwamba aukadaulo:
1.Voteshoni yovotera: 6.3kV, 6.6kV, 6.6/√3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11/√3kV, chonde zisonyezedwe mu dongosolo ngati mukufuna mphamvu ina yapadera.
2.Rated mphamvu: 33 ~ 334kvar chonde anasonyeza mu dongosolo ngati mukufuna mphamvu ina yapadera.
3.Kulekerera kwamphamvu: -5 ~ 15%.
4.Loss angel tangential value: film & papaer medium tg θ≦0.08%,filimu sing'anga tg θ≦0.05%.
5.Withstand voteji: imatha kukwanitsa AC2.15 kapena DC4.3 nthawi yomwe idavotera voteji pakati pa utoto wocheperako, womaliza pafupifupi 10s popanda kuswa kapena kung'anima, BIL: 6kV (30kV), 10kV (42Kv).
6.Kutulutsa kwaulere: kumakhala ndi kukana kwamkati, 10min mutatha kudula mphamvu, mphamvu yotsalira idzachepetsa mpaka 75V kuchokera ku √2 Un.
7. Max. Pakalipano: ikuyenda bwino pansi pa 1.3 nthawi yovotera magetsi, kupitirira mphamvu, kulekerera kwabwino ndi mafunde a harmonic omwe sangapitirire 1 min maola 24 aliwonse.
8.Max.Current: kuthamanga bwino pansi pa 1.3 nthawi oveteredwa voteji, pa voteji, mphamvu zabwino kulolerana ndi mafunde harmonic amene sangathe 1.43 nthawi oveteredwa panopa.
9.Standard: GB/T 112024.1-2001, IEC6087:1997.
OSIYANA PHASE MPHAMVU CAPACITOR
Chitsanzo BAM | Adavotera Voltage (kV) | Zotulutsa Zoyezedwa (kVAr) | Mphamvu Zoyezedwa (uF) | Idavoteredwa Panopa (A) |
6.3-25-1W | 6.3 | 25 | 2.006 | 3.968 |
6.3-30-1W | 6.3 | 30 | 2.406 | 4.762 |
6.6/√3-25-1W | 6.6/√3 | 25 | 5.481 | 6.561 |
6.3/√3-30-1W | 6.6/√3 | 30 | 6.577 | 7.873 |
6.3/√3-50-1W | 6.6/√3 | 50 | 10.96 | 13.12 |
10.5-25-1W | 10.5 | 25 | 0.722 | 2.38 |
10.5-30-1W | 10.5 | 30 | 0.886 | 2.857 |
10.5-50-1W | 10.5 | 50 | 1.444 | 4.762 |
11/√3-30-1W | 11/√3 | 30 | 2.368 | 4.724 |
11/√3-50-1W | 11/√3 | 50 | 3.946 | 7.873 |
6.3-30-1W | 6.3 | 30 | 2.4 | 4.76 |
6.3-50-1W | 6.3 | 50 | 4 | 7.9 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | makumi awiri ndi mphambu zinayi | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
10.5-50-1W | 10.5 | 50 | 1.44 | 4.8 |
10.5-100-1W | 10.5 | 100 | 2.9 | 9.5 |
10.5-150-1W | 10.5 | 150 | 4.3 | 14.3 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-300-1W | 10.5 | 300 | 8.67 | 28.6 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |
11/√3-50-1W | 11/√3 | 50 | 3.95 | 7.87 |
11/√3-100-1W | 11/√3 | 100 | 7.89 | 15.75 |
11/√3-150-1W | 11/√3 | 150 | 11.84 | 23.6 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-300-1W | 11/√3 | 300 | 23.68 | 47.2 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
6.6/√3-50-1W | 6.6/√3 | 50 | 10.96 | 13.12 |
6.6/√3-100-1W | 6.6/√3 | 100 | 21.9 | 26.24 |
6.6/√3-150-1W | 6.6/√3 | 150 | 32.9 | 39.36 |
6.6/√3-200-1W | 6.6/√3 | 200 | 43.8 | 52.48 |
6.6/√3-300-1W | 6.6/√3 | 300 | 65.8 | 78.7 |
6.6/√3-334-1W | 6.6/√3 | 334 | 73.2 | 87.6 |
11-100-1W | 11 | 100 | 2.63 | 9.1 |
11-150-1W | 11 | 150 | 3.95 | 13.6 |
11-200-1W | 11 | 200 | 5.26 | 18.2 |
11-300-1W | 11 | 300 | 7.89 | 27.3 |
11-334-1W | 11 | 334 | 8.79 | 30.4 |
12-100-1W | 12 | 100 | 2.2 | 8.33 |
12-150-1W | 12 | 150 | 3.3 | 12.5 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-300-1W | 12 | 300 | 6.64 | 25 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
12/√3-100-1W | 12/√3 | 100 | 6.63 | 14.4 |
12/√3-150-1W | 12/√3 | 150 | 9.95 | 21.7 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-300-1W | 12/√3 | 300 | 19.9 | 43.3 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12/√3-400-1W | 12/√3 | 400 | 26.54 | 57.74 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-150-1W | 6.3 | 150 | 12 | 23.8 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | makumi awiri ndi mphambu zinayi | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
6.6-100-1W | 6.6 | 100 | 7.3 | 15.2 |
6.6-150-1W | 6.6 | 150 | 11 | 22.7 |
6.6-200-1W | 6.6 | 200 | 14.6 | 30.3 |
6.6-300-1W | 6.6 | 300 | makumi awiri ndimphambu ziwiri | 45.5 |
6.6-334-1W | 6.6 | 334 | 24.4 | 50.6 |
6.6/√3-100-1W | 6.6/√3 | 100 | 21.9 | 26.24 |
6.6/√3-150-1W | 6.6/√3 | 150 | 32.9 | 39.36 |
6.6/√3-200-1W | 6.6/√3 | 200 | 43.8 | 52.48 |
6.6/√3-300-1W | 6.6/√3 | 300 | 65.8 | 78.7 |
6.6/√3-334-1W | 6.6/√3 | 334 | 73.2 | 87.6 |
11/√3-100-1W | 11/√3 | 100 | 7.89 | 15.75 |
11/√3-150-1W | 11/√3 | 150 | 11.84 | 23.6 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-300-1W | 11/√3 | 300 | 23.68 | 47.2 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.3 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.2 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |